The information in Fig. 12 show that the intensity transition transducer lessens the extent of the blunders by a component of around 8 for a VIG with support point division of 20 mm. These decrease factors are less for additional generally dispersed points of support, with upsides of around 4 and 3 for VIGs with point of support partitions of 30 mm and 40 mm separately. The decrease factors are basically free of glass thickness. These diminished conceivable estimation mistakes might in any case be huge, in any event, for enormous estimation regions and when the impacts of radiative intensity stream are incorporated. Work on this matter is proceeding.

As noted before, plan information of the intensity transition transducers in commercial intensity stream meter instruments are not normally publically accessible. By and large, it is in this way impractical to make a deduced judgment of whether such an instrument will lessen the blunders examined above to satisfactory levels. This can be resolved tentatively, in any case, essentially by utilizing the instrument to quantify the intensity course through the VIG example at the two outrageous positions ‒ with the focal point of the estimating region over a point of support, and mid-way between 4 support points.

The limited intensity course through the help points of support in VIGs can prompt huge varieties in the estimation of the warm insulating properties while utilizing enormous region instruments that straightforwardly contact the glass surfaces. The greatest and least intensity streams happen (not really separately) when the focal point of the area is straight over a point of support, and straight over the focal point of a unit cell.

These varieties can prompt mistakes in the deliberate intensity stream. As a rule, there is no basic approach to situating the estimating region comparative with the support point exhibit so it estimates the typical intensity move through the examples. There are, in any case, two exemptions for this. Right off the bat, the mistakes don't happen on the off chance that the element of the square estimating region is an indispensable numerous of the support point detachment. Furthermore, the mistakes are zero in the event that the focal point of an estimating area of aspect equivalent to a whole number) is found halfway between the places of least and greatest intensity stream. Check out SGCC vacuum double glazing.

The size of the mistakes diminishes roughly contrarily with the component of the estimating region because of the relatively bigger number of complete unit cells that add to the intensity stream. The blunders are additionally less for heat stream meters than for watched hot plates because of sidelong intensity stream in the intensity motion transducers. The degree of this decrease relies upon the particular plan of the intensity transition transducer in this instrument. The blunders might be acceptably little for VIGs with thick glass sheets and firmly divided points of support, and for exceptionally enormous region heat stream meter instruments. It tends to be resolved tentatively if so by estimating the greatest and least intensity move through the example.